Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Braz. j. med. biol. res ; 46(11): 936-942, 18/1jan. 2013. tab, graf
Article in English | LILACS | ID: lil-694024

ABSTRACT

The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s-1·MBq-1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99mTc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99mTc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.

2.
Arq. bras. med. vet. zootec ; 44(4): 297-310, ago. 1992. ilus, tab
Article in Portuguese | LILACS | ID: lil-240041

ABSTRACT

Foram determinadas as sensibilidades de três linhagens celulares (ST, SK6 e PK15) a duas amostras de parvovírus suíno (PVS-1 e NADL-2) e efetuadas as curvas de replicaçäo viral, através dos efeitos citopáticos e títulos hemoaglutinantes determinados com intervalo de 12 h, durante um período de estudo de 120 h. A maior sensibilidade foi verificada pela linhagem celular ST, seguida pela célula SK6, sendo a célula PK15 a menos sensível


Subject(s)
Animals , Cell Line , Parvovirus , Swine
SELECTION OF CITATIONS
SEARCH DETAIL